Light gauge steel stud shear wall.
Ii shear wall values for light weight steel framing preface this report presents the results of monotonic and cyclic tests of 42 full size cold formed steel framed shear walls sheathed with plywood oriented strand board osb and gypsum wallboard gwb.
Light frame bearing wall structures with gravity systems constructed of cfs joists or trusses supported by cfs load bearing walls and a lfrs using cfs.
Steel framing wall stud design aisi s211 07.
They cut light gauge metal studs up to 6 wide.
Special lengths are available.
Available in galvanized per astm a 653 or equal.
No longer just a division between space.
Materials a light gauge steel meeting the physical and galvanization requirements of astm a 653 or equal.
Shear φ v 0 80 web.
The jr cuts 20 gauge and lighter that s used in store interior fit up like sofits etc.
The wall stud web crippling calculations assume the following.
Track thickness equal to or greater than the stud thickness both flanges of the stud attached to the track studs not adjacent to wall openings or discontinuities in the track.
Primejoist s unique configuration delivers increased strength and stiffness minimizing or eliminating the use of built up joist sections in.
No longer just studs tracks and headers.
The findings provided a basis for continued research and development efforts leading to.
Design by testing is a possibility if large numbers of identical walls are.
Laterally bracing in steel stud wall systems and ornamental lathing.
A number of construction types take advantage of cold formed steel for all or part of the lfrs of a building.
B shape and dimensions shown at left.
Primejoist is a revolutionary addition to the light gauge steel stud industry producing significant economies in both design and installation when compared with conventional c shaped studs.
Sheathed light gauge steel lgs shear walls are often used in structures as load bearing elements against wind and earthquake actions.
Except where indicated otherwise minimum stud size is 3 1 2 x 1 5 8 x 0 033 in.
The design of walls is often complicated by the lack of analytical methods for the evaluation of the strength and rigidity.
In table 3 thicknesses of 0 0433 are indicated for certain cases.
Shear center of typical c stud.
C length 10 0 and 20 0.